Assa Abloy DK-26 Instructions d'exploitation Page 5

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 23
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 4
PN# 500-16900
Page 4 Rev. D, 12/11
FIG. 3: OVERVIEW OF CPU BOARD
SRC
REX
UCD HCD NCX CX
NOX
NC2 C2
NO2
NC1 C1
NO1
GRN YEL RED BLU
WHT
BLK GRY BRN BGE ORG PNK
VIO
AC IN F DC IN/OUT
+
PRGM
HARD
CODE
CODE
MICROPROCESSOR
AUX.
SOCKET
DPDT RELAY
SPDT
RELAY
12/24 AC POWER
FREE TERMINAL
12/24 DC POWER +
12/24 DC NEGATIVE
DC TERMINALS MAY
ALSO BE USED AS
OUTPUT TO POWER
DC LOCK, IF AC
POWER IS SUPPLIED
BEEPER
COMMON
RED LED
GRN LED
YEL LED
KEYS
KEYS
KEYS
KEYS
KEYS
KEYS
KEYS
VIOLET
PINK
ORANGE
BEIGE
BROWN
GRAY
BLACK
WHITE
BLUE
RED
YELLOW
GREEN
PUSH TO SET PROGRAM MODE
PUSH TO PROGRAM HARD CODE
COM. FOR REX, UCD, HCD TERMS
REX INPUT (REMOTE RELEASE)
DISABLE ALL USER CODES
DISABLE HARD CODE
LOCK CONTROL
RELAY CONTACTS
PROGRAM
RELAY
CONTACTS
KEYPAD CABLE
PS1
PS2
PS3
3.3.2 DC LOCK WITH AC POWER
For convenience and economy, most DC electric locks can be operated from an AC transformer
when the DK-26 is used. Select a transformer of the same voltage as the lock (12 or 24). The
CPU board converts the input AC to DC to operate the lock. Make sure the capacity of the
transformer is large enough to operate both the DK-26 and the lock and that the transformer
is UL listed under the UL 294 standard. The lock must accept full wave rectified DC
power. This is true of most DC locks (including Securitron’s Magnalocks) but some specialty
units require regulated DC power. You must operate those as described in the next Section.
Note finally that many DC lock installations call for battery backup. To achieve this, you must
employ a DC battery backup power supply and also follow the wiring description in Section
3.3.3.
DC locks come in “fail secure” and “fail safe” versions. A fail secure lock is secure when not
powered and a fail safe lock is secure when powered. All magnetic locks are fail safe. Figure
4 shows AC power being input to the AC terminals. The DC terminals furnish output power for
RELAY CONTACTS
RATED AT 5 AMPS